VITA Technologies
  • VME
  • XMC
  • FMC
  • PMC
  • VNX
  • VPX
Menu
  • VME
  • XMC
  • FMC
  • PMC
  • VNX
  • VPX
  • Articles
  • White Papers
  • Products
  • News
Menu
  • Articles
  • White Papers
  • Products
  • News
  New Products  LeCroy Announces SDAIII-CompleteLinQ Multi-Lane Serial Data Analysis Products for High-bandwidth Oscilloscopes
New Products

LeCroy Announces SDAIII-CompleteLinQ Multi-Lane Serial Data Analysis Products for High-bandwidth Oscilloscopes

LeCroyLeCroy—July 5, 20120
FacebookTwitterPinterestLinkedInTumblrRedditVKWhatsAppEmail



Chestnut Ridge, NY, July 5, 2012 – LeCroy Corporation announces SDAIII-CompleteLinQ – the only serial data analysis package that simultaneously performs eye, jitter, vertical noise, and crosstalk analysis on up to four lanes, with quick and easy lane-to-lane comparisons.

SDAIII-CompleteLinQ Solves Multi-lane Serial Data Analysis Challenges

Mobile and cloud computing is driving demand for higher data throughput. Existing and emerging standards, such as PCIe Gen3, 40/100GBase-R, and InfiniBand, are meeting these needs by utilizing multiple serial data lanes, as well as increasing data rates on each lane—up to 28 Gb/s—to achieve very high data throughput.

Higher-speed data rates increase the characterization, debug, and compliance test challenges on even a single lane of serial data. Determining the root cause of eye closure in the channel between the transmitter and receiver is the primary challenge. Simulating where engineers cannot place a probe or otherwise access the signal becomes critical.

The “paralleling” of high-speed serial data transmissions results in additional challenges. Crosstalk between lanes, or coupled from other sources, and other signal integrity issues can be significant problems. Quickly and simultaneously viewing performance of multiple lanes, measuring vertical noise, and determining pattern dependency of the jitter and the noise is the key to understanding root-cause of poor system performance. Only LeCroy has the combination of real-time signal acquisition and serial data analysis capabilities that will allow you to quickly and successfully design high-speed and/or multi-lane serial data systems.

Unique Simultaneous Multi-Lane Eye and Jitter Measurements and Analysis

The SDAIII-CompleteLinQ extends LeCroy’s serial data analysis toolsets to include the simultaneous analysis of up to four lanes of serial data traffic. With multi-lane analysis, engineers can quickly view eye diagrams on all lanes, or use the multi-lane capability to analyze a single lane at multiple points using LeCroy differential probes or the VirtualProbe option. SDAIII-CompleteLinQ can also show multiple analyses of a single serial data signal – ideal for comparing different equalization schemes with the Eye Doctor II option.

More stories

Curtiss-Wright Controls Defense Solutions Introduces Industry’s First Air-Flow-Through (AFT)-cooled NVIDIA Fermi Architecture GPGPU VPX Engine

June 28, 2012

VPX RTM Access Simplified: Technobox 8600 Paddle Card Eases Rear Signal Access and Interconnects for VPX

February 2, 2018

PROTOKRAFT INTRODUCES HORNET SERIES PANEL MOUNTED D38999 ETHERNET SWITCHES

July 20, 2011

ALT Software releases optimized OpenGL ES and OpenVG graphics drivers for the POWERVR MBX graphics core on Wind River Linux and VxWorks

December 14, 2009

LaneScape™ Comparison Mode

SDAIII-CompleteLinQ also solves the problem of lane-to-lane-comparisons with LaneScape™ Comparison Mode and the new Reference Lane. Users can store and display the complete analysis of a lane into the Reference Lane and use a LaneScape display mode to compare the analysis of 1, 2 or all lanes simultaneously.

The Reference Lane allows engineers to easily perform multi-scenario testing. One such test is aggressor on/off analysis, which allows users to measure eye and jitter characteristics with a neighboring aggressor lane turned on, store this analysis to the Reference Lane, and then perform the analysis with the aggressor turned off. The Reference Lane can then be compared to other lanes using the LaneScape display mode.

Vertical Noise Measurements and Crosstalk Analysis

The Crosstalk and CrossLinQ packages that are part of the SDAIII-CompleteLinQ product family provide vertical noise measurements and crosstalk analysis tools for complete aggressor/victim analysis. One of three dual-Dirac models can be used to measure and separate noise into total (Tn), random (Rn) and deterministic (Dn) components, and further decompose Dn into Intersymbol Interference Noise (ISIn) and Periodic Noise (Pn). Only LeCroy can perform this analysis on real-time oscilloscopes. Similar to jitter analysis, noise can be viewed as a noise track, histogram and spectrum, providing insight into the vertical noise resulting from coupling to other active serial data lanes or other interference sources. The Crosstalk Eye shows the probabilistic extent of noise both inside and outside the eye, quickly showing the impact of excessive noise that is not possible to see in a traditional eye diagram.

Integration with Advanced Signal Integrity Toolkits

The new VirtualProbe and existing Eye DoctorII packages integrate into the SDAIII-CompleteLinQ dialog. With EyeDoctorII, users can configure transmitter emphasis and receiver equalization independently for each lane, and view how the eye and jitter results are affected.

With VirtualProbe, users can see what the signal looks like where a probe cannot be placed, while also de-embedding fixture and emulating channels modeled by S-parameters. When used in conjunction with the Crosstalk and CrossLinQ packages, VirtualProbe can use 8- and 12-port S-parameter models in a unique “XTalk” block that characterizes the coupling between multiple lanes. LeCroy SPARQ Signal Integrity Network Analyzers can make S-parameter measurements on up to 12 ports, at a fraction of the cost of a VNA.

The SDAIII-CompleteLinQ product integrates all of LeCroy’s eye, jitter, vertical noise, and crosstalk analysis features, along with the signal integrity capabilities of EyeDoctorII and VirtualProbe.

Compatibility

SDAIII-CompleteLinQ products are compatible with WavePro®/SDA/DDA 7 Zi/Zi-A, WaveMaster®/SDA/DDA 8 Zi/Zi-A, LabMaster 9 Zi-A and 10 Zi series oscilloscopes. Existing users of these products, or of the SDAII package, can upgrade to any of the SDAIII-CompleteLinQ products.

About LeCroy

LeCroy Corporation is a worldwide leader in serial data test solutions, creating advanced instruments that drive product innovation by quickly measuring, analyzing, and verifying complex electronic signals. The Company offers high-performance oscilloscopes, serial data analyzers, and global communications protocol test solutions used by design engineers in the computer and semiconductor, data storage device, automotive and industrial, and military and aerospace markets. LeCroy’s 45-year heritage of technical innovation is the foundation for its recognized leadership in “WaveShape Analysis”—capturing, viewing, and measuring the high-speed signals that drive today’s information and communications technologies. LeCroy is headquartered in Chestnut Ridge, New York. Company information is available at www.lecroy.com.

FacebookTwitterPinterestLinkedInTumblrRedditVKWhatsAppEmail
Avnet, Inc. Announces Acquisition of Passive Specialist Altron GmbH & Co. KG
Klocwork Passes 1000 Customer Milestone With Record First Half Performance
Related posts
  • Related posts
  • More from author
Eletter Products

SPONSORED: Rugged 1/2 ATR Aligned to SOSA, CMFF and SAVE Ready

January 30, 20250
Consortia and Working Groups

Call for Consensus Body Members to Reaffirm ANSI/VITA 67.1-2019 – Coaxial Interconnect on VPX, 4 Position SMPM Configuration

January 28, 20250
Eletter Products

SPONSORED: SAVE Compliant Chassis for VPX and SOSA Aligned Systems

January 28, 20250
Load more
Read also
Eletter Products

SPONSORED: Rugged 1/2 ATR Aligned to SOSA, CMFF and SAVE Ready

January 30, 20250
Consortia and Working Groups

Call for Consensus Body Members to Reaffirm ANSI/VITA 67.1-2019 – Coaxial Interconnect on VPX, 4 Position SMPM Configuration

January 28, 20250
Eletter Products

SPONSORED: SAVE Compliant Chassis for VPX and SOSA Aligned Systems

January 28, 20250
Eletter Products

SPONSORED: Introducing AirBorn’s 2300W+ VPX Power Supply

January 28, 20250
Consortia and Working Groups

VITA announces formation of VITA 100 working groups

January 13, 20250
Articles

VITA Technologies 2025 Application Guide is here!

December 13, 20240
Load more

Recent Comments

No comments to show.
  • Articles
  • White Papers
  • Products
  • News
Menu
  • Articles
  • White Papers
  • Products
  • News
  • VME
  • XMC
  • FMC
  • PMC
  • VNX
  • VPX
Menu
  • VME
  • XMC
  • FMC
  • PMC
  • VNX
  • VPX

© 2023 VITA Technologies. All rights Reserved.