  Articles  VITA 41 (VXS) plays a key role in the VITA ecosystem
Articles

VITA 41 (VXS) plays a key role in the VITA ecosystem

Melissa Heckman, Elma BustronicMelissa Heckman, Elma Bustronic—December 31, 20090
FacebookTwitterPinterestLinkedInTumblrRedditVKWhatsAppEmail

Since its inception in 2004 and formal release in 2006, VITA 41 (VXS) has become a vital part of the VME ecosystem. Its market share is growing in niche applications including customized open-standards-based designs.

The reason: VXS offers a significant performance boost over VME64x with a slot-to-slot bandwidth of 3,050 MBps, and its backwards compatibility is particularly attractive in many mil/aero, industrial, and medical applications. A higher-speed multigig connector in the P0 position and the added switched fabric capability significantly boost performance. The VITA Standards Organization (VSO) has released VXS standards and subspecifications steadily over the past several years, and activity is ongoing.

Back to basics: Reviewing VXS 41.0-41.2

The base standard, VITA 41.0, defines the payload and switch slot connectors, pinouts, mechanical layout, and alignment keying. The switch slot has:

  • High-speed connectors for the switched fabric
  • A sideband connector for VMEbus signals such as SYSFAIL# and SYSRESET#
  • A six-pin power connector
More stories

Kovid Krazy

November 19, 2020

3U VPX tackles needs of today’s net-centric battlefield

April 20, 2009

VPX eyes new frontiers

June 2, 2015

Hall of Fame

April 11, 2017

The VITA 41.0 standard requires glyphs on the front panel and the backplane. There is a glyph for the payload slot and the switch slot. The payload and switch slots are keyed to prevent incorrect board insertion.

VITA 41.1 is the 4x InfiniBand Protocol standard. It assigns the signals for InfiniBand communication over the 41.0 data links. The standard defines requirements and recommendations for the use of the data links, InfiniBand in-band management, and I2C out-of-band management. InfiniBand uses 2.5 Gbps bidirectional links as the 1x base and in this standard scales to 4x links.

VITA 41.2 is the 4x Serial RapidIO Protocol standard. The standard specifies the Serial RapidIO signals over the 41.0 data links. It provides guidelines for the use of the Serial RapidIO links, in-band management, and I2C out-of-band management. Serial RapidIO employs 1, 2.5, or 3.125 Gbps bidirectional links as the 1x links and scales to 4x links used in this standard.

What’s new with VXS?

In recent VXS standard activity, VITA 41.6, 1x GbE Control Channel, has been approved by the VSO group and has gone to ANSI for accreditation. The control channel is parallel to the data plane defined in 41.0 and operates independently of the data plane. VITA 41.6 is implemented using SGMII, a high-speed serial Serializer/Deserializer (SERDES) link over a transmit and receive pair. The physical link operates at 1.25 Gbps. There are up to two links (250 MBps) per payload card. The pins for the control channel, which provides important management functions for VXS systems, are separate from the data plane.

VITA 41.8, 10 GbE Protocol Layer, specifies 10 GbE as the primary fabric using four XAUI ports at 3.125 Gbps each. An alternative configuration uses 10GBASE-KX4, which adds auto negotiation and better channel/backplane definition. VITA 41.8 is currently in ANSI ballot. This is an additional standard to add the high performance of 10 GbE to VXS, which wasn’t specified before this standard was created.

Looking to future VXS activity, the next standards slated for release from the VSO to ANSI for accreditation are VITA 41.3 (Gbps Baseband IEEE 802.3 Protocol Layer) and VITA 41.4 (4x PCI Express Protocol Layer). These standards – in addition to VITA 41.6 and VITA 41.8 – are propelling VXS into a vibrant future for years to come.

Melissa Heckman has been an Electrical Engineer with Bustronic since 1998 and can be contacted at [email protected].

FacebookTwitterPinterestLinkedInTumblrRedditVKWhatsAppEmail
VITA 41.6, 49.0, 49.1, and 58 achieve ANSI recognition
AIM’s New USB ARINC-429 Analyzer
Related posts
  • Related posts
  • More from author
Articles

Next-gen fiber optics for aviation: Expanded Beam performance with VITA 95/96

June 3, 20250
Articles

Embedded Tech Trends 2025 Wrapup

June 3, 20250
Consortia and Working Groups

VITA standards activity updates

June 3, 20250
Load more
Read also
Articles

Next-gen fiber optics for aviation: Expanded Beam performance with VITA 95/96

June 3, 20250
Articles

Embedded Tech Trends 2025 Wrapup

June 3, 20250
Consortia and Working Groups

VITA standards activity updates

June 3, 20250
Articles

Leveraging AI in standards

June 3, 20250
Eletter Products

SPONSORED: SpaceVPX Solutions From Pixus Technologies

May 28, 20250
Eletter Products

SPONSORED: Mission-Ready Chassis Management Aligned to SOSA®

May 28, 20250
Load more

Recent Comments

No comments to show.
  • Articles
  • White Papers
  • Products
  • News
Menu
  • Articles
  • White Papers
  • Products
  • News
  • VME
  • XMC
  • FMC
  • PMC
  • VNX
  • VPX
Menu
  • VME
  • XMC
  • FMC
  • PMC
  • VNX
  • VPX

© 2023 VITA Technologies. All rights Reserved.