VITA Technologies
  • VME
  • XMC
  • FMC
  • PMC
  • VNX
  • VPX
  • VME
  • XMC
  • FMC
  • PMC
  • VNX
  • VPX
  • Articles
  • White Papers
  • Products
  • News
  • Articles
  • White Papers
  • Products
  • News
  News  Consortia and Working Groups  Solicitation for Voters on ANSI Ballot of VITA 48.4
Consortia and Working Groups

Solicitation for Voters on ANSI Ballot of VITA 48.4

VITAVITA—November 15, 20170

The VITA 48.4 working group has completed the draft and has voted to take the draft through to the ANSI process to be recognized as an ANSI standard. Voter registration for voting for ANSI recognition of the following draft standard is now open :

More stories

Voter registration is now open for the following standard: – VITA 78, SpaceVPX

October 20, 2014

VXI Technology, Inc. to Host the LXI Consortium PlugFest

January 25, 2008

VITA Members Complete First VPX System Management Interoperability Workshop

September 23, 2014

ANSI and VITA Ratify ANSI/VITA 68 VPX Compliance Channel Standard

January 16, 2018

VITA 48.4-201x (New Standard), Liquid Flow Through VPX Plug-In Module Standard

This standard establishes the mechanical design interface control, outline and mounting requirements for a liquid-flow-through cooled plug-in unit to ensure the mechanical intermateability of 6U VPX liquid-flow-through cooled plug-in module within associated subracks. The connector layout remains common with VITA 46.. This plug-in module uses liquid flowing through an integral heat sink of the unit for cooling the electronic components and circuit boards. The quick disconnect coupling assemblies allow fluidic coupling to the chassis coolant manifold.

This ballot is open to both VITA members and non-members. You must register if you wish to participate in the ballots. Non-members should contact Jing Kwok, VITA Technical Director, for login credentials.

This solicitation will be open for 14 days. The roster will be vetted to ensure it meets balance, lack of dominance and openness rules. Following which a formal ballot will be sent to the roster for voting.

Closing Date: Tue, Nov 28 2017 2:00 pm PST

Please register ONLY IF you intend to vote. The ballot will be voided if we do not get enough returned votes.

VITA

E-cast: Safety Certification Key to Sharing the Sky for Avionics and UAVs
Pentek Introduces Cost-Effective Sentinel Intelligent Signal Scanning Recorder
Related posts
  • Related posts
  • More from author
Articles

VITA standards activity updates

December 1, 20250
Consortia and Working Groups

Ratification of VITA 93 – QMC: TEWS Technologies Welcomes a New Era in Modular I/O

September 30, 20250
Consortia and Working Groups

VITA standards activity updates

June 3, 20250
Load more
Read also

The VITA Technologies 2026 Resource Guide is here!

June 15, 20260

VITA Standards Update

June 15, 20260
Articles

VITA 100 and the next phase of embedded computing standards

June 15, 20260
Articles

VME in defense systems: A legacy of reliability, longevity, and determinism

June 15, 20260
Articles

MOSA, SOSA, and VITA explained: The standards behind VPX defense electronics

June 15, 20260
Eletter Products

SPONSORED: Mission-Ready Chassis Management Aligned to SOSA®

June 4, 20260
Load more

Recent Comments

No comments to show.
    • Articles
    • White Papers
    • Products
    • News
    • Articles
    • White Papers
    • Products
    • News
    • VME
    • XMC
    • FMC
    • PMC
    • VNX
    • VPX
    • VME
    • XMC
    • FMC
    • PMC
    • VNX
    • VPX

    © 2023 VITA Technologies. All rights Reserved.